On Fri, 5 Jul 2024 17:54:54 -0500, Snag <
Snag_one@msn.com> wrote:
On 7/5/2024 5:23 PM, Jim Wilkins wrote:
"Snag" wrote in message news:v69p2c$3erk6$1@dont-email.me...
Can you set up a relay lockout that whichever compressor is running
will cut power to the other ? An "or" gate type setup .
>
If you search for relay control logic circuits, that is called
"Exclusive-OR", XOR.
>
My understanding of logic circuits is rudimentary at best . Kinda
reminds me of algebra . It made my head hurt too .
With a pilotted contactor connect the NC contacts of the pilot on
compressor A in seried with the contactor coil on compressor B and
vise versa. If "A" is on no power to the coil of "B" - if "B" is on no
power to the coil of "A"