Sujet : Re: Extech EX410A DVM Don't Buy
De : JL (at) *nospam* gct.com (john larkin)
Groupes : sci.electronics.designDate : 05. Oct 2024, 15:52:25
Autres entêtes
Organisation : A noiseless patient Spider
Message-ID : <18k2gj5m5rjfnc1iabbtclnvdntpsfgtm2@4ax.com>
References : 1 2
User-Agent : ForteAgent/8.00.32.1272
On Fri, 04 Oct 2024 16:07:24 -0700, Jeff Liebermann <
jeffl@cruzio.com>
wrote:
On Thu, 03 Oct 2024 14:46:46 -0700, john larkin <jl@glen--canyon.com>
wrote:
>
Extech EX410A DVM Don't Buy
>
The auto power off is incredibly stupid. I'm going to throw mine away
and get something usable.
>
What don't you like about the auto power off feature in the EX410A?
It shuts off in the middle of a measurement, and you have to rotate
the very klunky range knob all the way back to OFF and then all the
way back to where it was.
It's OK for one-time measurements I guess, but terrible for bench
experiments.
Extech was planning to introduce some thermal imagers, so FLIR bought
them to stop it. That's all FLIR really cares about.