Re: Question about Oxley RFI suppression filters FLTM/P/5000

Liste des GroupesRevenir à se design 
Sujet : Re: Question about Oxley RFI suppression filters FLTM/P/5000
De : erichpwagner (at) *nospam* hotmail.com (piglet)
Groupes : sci.electronics.design
Date : 30. Jan 2025, 15:08:16
Autres entêtes
Organisation : A noiseless patient Spider
Message-ID : <vng14g$2vlfc$1@dont-email.me>
References : 1
User-Agent : NewsTap/5.5 (iPhone/iPod Touch)
Jean-Pierre Coulon <coulon@cacas.pam.oca.eu> wrote:
I have put some on an amplifier box for my + and 5 V supplies. But yet a
ripple on either supply signically contaminates my outut signal.
 
AFAIK they represent a 6-uH series inductor and an about 5-nF parallel
capacitor. Is this inductor a coil or a toroid? If it is a coil it could
radiate a signficant magnetic field, contaminating my input signal.
 
Regards

Sorry I don’t know the internal construction but suspect the inductor is
possibly not a coil but merely the central conductor passing through a
ferrite sleeve. In those feedthroughs the capacitors are often annular too
so nothing is left to chance.

You haven’t said what the frequency is of the ripple that you observe,
those devices will have negligible effect at powerline frequency.

--
piglet

Date Sujet#  Auteur
30 Jan 25 * Question about Oxley RFI suppression filters FLTM/P/500010Jean-Pierre Coulon
30 Jan 25 +* Re: Question about Oxley RFI suppression filters FLTM/P/50004piglet
30 Jan 25 i`* Re: Question about Oxley RFI suppression filters FLTM/P/50003Jean-Pierre Coulon
30 Jan 25 i `* Re: Question about Oxley RFI suppression filters FLTM/P/50002piglet
31 Jan 25 i  `- Re: Question about Oxley RFI suppression filters FLTM/P/50001Jean-Pierre Coulon
30 Jan 25 `* Re: Question about Oxley RFI suppression filters FLTM/P/50005john larkin
31 Jan 25  `* Re: Question about Oxley RFI suppression filters FLTM/P/50004Jean-Pierre Coulon
31 Jan 25   `* Re: Question about Oxley RFI suppression filters FLTM/P/50003Jeroen Belleman
31 Jan 25    `* Re: Question about Oxley RFI suppression filters FLTM/P/50002Phil Hobbs
31 Jan 25     `- Re: Question about Oxley RFI suppression filters FLTM/P/50001john larkin

Haut de la page

Les messages affichés proviennent d'usenet.

NewsPortal