Sujet : Re: PSU Ripple Update
De : jl (at) *nospam* 997PotHill.com (John Larkin)
Groupes : sci.electronics.repair sci.electronics.designDate : 18. Mar 2024, 03:28:04
Autres entêtes
Organisation : Highland Tech
Message-ID : <bd9fvi5v309durp85o1tflgv4rrpm1sn3u@4ax.com>
References : 1 2 3 4
User-Agent : Forte Agent 3.1/32.783
On Mon, 18 Mar 2024 01:23:18 GMT, Bertrand Sindri
<
bertrand.sindri@yahoo.com> wrote:
In sci.electronics.design Cursitor Doom <cd@notformail.com> wrote:
On Sun, 17 Mar 2024 16:05:46 -0400, bitrex <user@example.net> wrote:
>
You sure you got your probe division/scope division configured
congruently?
Yes, it's on 1x @ 5ms.
>
The question, which appears to have flown straight over your head, was:
Does the scope setting match the probe you are using?
>
I.e., is it a 1X probe (or a switchable probe on the 1X setting)?
>
Is the probe 1X, 10X, or some other X?
DC coupling, with zero somewhere low on the screen, would be more
meaningful.
We don't know if that is 1% ripple, or 50%. Or what the DC voltage is.
Or what the regulator drop is.
I like digital scopes, that flag zero and the trigger point.