On 5/15/24 01:33, Don wrote:
Jeroen Belleman wrote:
Phil Hobbs wrote:
John Larkin wrote:
Don wrote:
<snip>
The parasitic capacitance created between coax and its metal armor can
open a Pandora's box of potential problems.
>
Capacitance between the coax outer and the copper pipe? Proper coax
shouldn't have any external field.
>
If the whole system is really coaxial, that’s true. Leaky shields, ground
loops, and so on, will modify that.
>
Depending on the application, you may or may not care.
If the whole system is really coaxial, that’s true. Leaky shields, ground
loops, and so on, will modify that.
>
Depending on the application, you may or may not care.
>
I've been putting coax inside copper tubes or braids to measure
and/or reduce the transfer impedance (leakage). I did that to
measure small signals in a particle accelerator, which typically
has kicker magnets and RF cavities with kA currents and kV
voltages nearby.
>
A colleague developed a special low transfer impedance coax
cable for this sort of application. It had two screens with
intermediate magnetic shielding. It was unpleasant to work
with, because part of the magnetic shielding was a steel
spiral foil tape that was razor sharp. But it worked really
well.
Empirical observation always trumps theory for me. Did you ground [1]
the copper tubes or braids?
Both ends were connected to the connector shields. The point of
the exercise was to reduce transfer impedance, which at low
frequency (<1MHz) is simply proportional to screen resistance.
Jeroen Belleman