Sujet : Re: CO2 Funny
De : jl (at) *nospam* 650pot.com (john larkin)
Groupes : sci.electronics.designDate : 27. May 2024, 13:04:33
Autres entêtes
Message-ID : <oqo85j9g6jitrju94cv1n5894j7r45ir9e@4ax.com>
References : 1 2 3 4 5 6 7 8 9 10 11
User-Agent : ForteAgent/8.00.32.1272
On Mon, 27 May 2024 15:05:14 +1000, Bill Sloman <
bill.sloman@ieee.org>
wrote:
On 27/05/2024 4:22 am, Edward Rawde wrote:
"Bill Sloman" <bill.sloman@ieee.org> wrote in message news:v2uhs7$39s6m$1@dont-email.me...
On 26/05/2024 4:38 am, Edward Rawde wrote:
"Bill Sloman" <bill.sloman@ieee.org> wrote in message news:v2na16$1nvei$1@dont-email.me...
On 23/05/2024 3:52 am, john larkin wrote:
On Wed, 22 May 2024 18:10:58 +0100, Pomegranate Bastard <pommyB@aol.com> wrote:
>
<snip>
>
It usually takes a while to work out why they did it that way, and it's pretty much essential to spend that time before you start
fiddling with the circuit. That wasn't true of the guy who'd put in the 741. He was very much in the John Larkin "if it sort of
works, ship it" camp.
Which of John Larkin's products have you purchased and tested and what improvement
do you think should have been made before it was shipped?
>
Absolutely none of them. The timing gear he sells to the American
National Ignition Facility is based on a 1978 Hewlett Packard scheme,
written up in their journal, and it depends on starting up a 50MHz
free-running oscillator in a very predictable way.
Totally wrong, as usual. The NIF timing system is synchronous at
155.52 MHz across over 200 timing modules, about 2000 "clients"
triggered every shot.
https://highlandtechnology.com/Product/V880https://www.dropbox.com/scl/fi/74f60yne8cdlr53n1x1la/TUAP069.pdf?rlkey=4lp86ca0ztfuh055qyxtok9lm&dl=0>
Faster oscillators have less jitter, and while synchronising to a
continuously running faster oscillator twice may introduce extra jitter,
the net jitter on the time delay can be quite a bit less.
We deliver 1 ps timing resolution and a few ps RMS jitter to clients
across a facility the size of a football stadium.
We recently delivered our third system to NIF, the second generation
beamline amplitude modulators. This helped them achieve over-unity
fusion yield.
>
I had much the same problem in 1988 and went for a free-running 800MHz
oscillator.
>
It turns out that the first version of John's 50MHz oscillator had a
nasty - if small - sub-harmonic oscillation and he's finally found a
better version.
It did not.