Re: Researchers achive real time detection of low gas concentrations

Liste des GroupesRevenir à se design 
Sujet : Re: Researchers achive real time detection of low gas concentrations
De : JL (at) *nospam* gct.com (john larkin)
Groupes : sci.electronics.design
Date : 13. Jan 2025, 17:46:40
Autres entêtes
Organisation : A noiseless patient Spider
Message-ID : <35gaoj1neppjj2ffdom6cmdk6q5ig128ee@4ax.com>
References : 1 2
User-Agent : ForteAgent/8.00.32.1272
On Tue, 14 Jan 2025 01:07:41 +1100, Bill Sloman <bill.sloman@ieee.org>
wrote:

On 13/01/2025 5:15 pm, Jan Panteltje wrote:
Researchers achieve real-time detection of low gas concentrations
  https://www.sciencedaily.com/releases/2025/01/250109125523.htm
   Allowing gas detection and identification in just seconds,
   approach using a coherent control strategy offers promise for
   real-time monitoring in environmental, health and industrial applications
Source:
  Optica
Summary:
Researchers have developed a method for quickly detecting and identifying
  very low concentrations of gases, which, could form the basis for highly
  sensitive real-time sensors for applications such as environmental monitoring,
  breath analysis and chemical process control.
 
Interesting method to stop a quartz tuning fork
>
It's a fairly old-fashioned technique - infra-red spectroscopy has been
around for a whole,and if you want to detect low gas concentrations you
could always use long-path-length absorbtion cells.
>
Ring-down detectors are an interesting variant on that approach.
>
The tuning fork detector may be a novel innovation, but it's less
obvious that is a useful one.
>
"Stopping" a high-Q resonator fast is easy enough, but then you have to
wait until the resonant movement builds up again - unless you have one
of John Larkin's fast-start resonant devices.

Starting a resonator-based oscillator is trivial,  just get the diff
equation initial conditions right.

The trick to an instant-start oscillator is really how to stop it,
totally quench the resonator, so memories of ringing from the previous
shot doesn't influence the next one.

HP made one delay generator that used a quartz crystal as the
triggered resonator. I met the guy who designed that and he was still
suffering PTSD.

HP and Tek used triggered delay-line oscillators in many instruments.
They can be stopped fairly well by terminating both ends.


Date Sujet#  Auteur
13 Jan 25 * Researchers achive real time detection of low gas concentrations4Jan Panteltje
13 Jan 25 `* Re: Researchers achive real time detection of low gas concentrations3Bill Sloman
13 Jan 25  `* Re: Researchers achive real time detection of low gas concentrations2john larkin
14 Jan 25   `- Re: Researchers achive real time detection of low gas concentrations1Bill Sloman

Haut de la page

Les messages affichés proviennent d'usenet.

NewsPortal