Re: Failed water pump and sump query

Liste des GroupesRevenir à se repair 
Sujet : Re: Failed water pump and sump query
De : NOTsomeone (at) *nospam* microsoft.invalid (GB)
Groupes : sci.electronics.repair uk.d-i-y
Date : 03. Feb 2025, 20:31:25
Autres entêtes
Organisation : A noiseless patient Spider
Message-ID : <vnr5id$1dq53$1@dont-email.me>
References : 1 2 3
User-Agent : Mozilla Thunderbird
On 03/02/2025 19:01, N_Cook wrote:
On 03/02/2025 17:45, Liz Tuddenham wrote:
N_Cook <diverse@tcp.co.uk> wrote:
>
Only made a preliminary check o this 1KW pump and float switch in a
sump, prior to dismantling ad exploring further.
Sump full of water but no pump action. Moving the float about made no
differece. Tapping the pump casing made the pump work until the float
switch dropped to the cut off point.
Refilling the sump and again no pump action until tapping the casing and
again stopping properly. I cannot see what in the way of sticky motor
brush or loose/corroded contact inside the motor housing could produce
this symptom.
>
You haven't said what sort of motor it is, but if it is a commutator
motor with brushgear, the fault could be worn-down brushes to the point
where one of them is almost-but-not-quite touching the commutator.
Tapping the motor gives some sort of contact and then the vibration of
the motor allows it to touch the commutator often enough to keep it
running.  This will give a fireworks display around the commutator and
will do considerable damage if it continues.
>
If it is not a brush motor, a similar thing can happen if the terminals
have become loose.  The sudden shock torque as the motor starts is
enough to make contact and vibration will keep it running; then the
contact is lost again after the motor has stopped.
>
The first things you need to check are what type of motor it is and
whether the supply is reaching the terminals in the connection box on
the motor casing.
>
 The pump is a JTFS Mini Micro domestic sewage pumping station,
probably JTFS190NN
No type technical details found but no obvious external  starter cap outside the motor casing or casig bulge.
The other consideration is it was installed 10 years ago, tested working then, but never heard to be working since.
It should have worked in a flood situation last year but it did not (automatically of its own accord that is) , no maintainece or testing or inspection in those 10 years by the owner or anyone else.
My BIL has a sump pump for his basement. It deals with any water penetrating, as well as the stuff from the toilet in the basement. It needed replacement, but that only cost around £70-80. Having seen that your one costs around £800, I can see why you are so interested in repairing it!

Date Sujet#  Auteur
3 Feb 25 * Failed water pump ad sump query20N_Cook
3 Feb 25 +* Re: Failed water pump ad sump query18Liz Tuddenham
3 Feb 25 i`* Re: Failed water pump and sump query17N_Cook
3 Feb 25 i +* Re: Failed water pump and sump query12GB
3 Feb 25 i i+* Re: Failed water pump and sump query10N_Cook
4 Feb 25 i ii+- Re: Failed water pump and sump query1GB
25 Feb 25 i ii`* Re: Failed water pump and sump query8N_Cook
25 Feb 25 i ii +- Re: Failed water pump and sump query1Liz Tuddenham
25 Feb 25 i ii +* Re: Failed water pump and sump query5Thomas Prufer
25 Feb 25 i ii i+* Re: Failed water pump and sump query2N_Cook
25 Feb 25 i ii ii`- Re: Failed water pump and sump query1Thomas Prufer
27 Feb 25 i ii i`* Re: Failed water pump and sump query2Allodoxaphobia
27 Feb 25 i ii i `- Re: Failed water pump and sump query1Thomas Prufer
27 Feb 25 i ii `- Re: Failed water pump and sump query1Liz Tuddenham
11 Feb 25 i i`- Re: Failed water pump and sump query1GB
3 Feb 25 i `* Re: Failed water pump and sump query4Liz Tuddenham
3 Feb 25 i  +* Re: Failed water pump and sump query2N_Cook
4 Feb 25 i  i`- Re: Failed water pump and sump query1GB
4 Feb 25 i  `- Re: Failed water pump and sump query1ehsjr
3 Feb 25 `- Re: Failed water pump ad sump query1Allodoxaphobia

Haut de la page

Les messages affichés proviennent d'usenet.

NewsPortal