http://easthope.ca/TerminalBlock.jpgJuding from the apparent size of the conductors in your picture, tinning is
definitely not recommended. If they're available in a small size, properly
crimped wire ferrules would be the most recommended method of making these
terminations.
There is too much "compression creep" with tinned wires as I've experienced in
the past.