Sujet : Re: Tripp Lite BCPERS450 UPS
De : bp (at) *nospam* www.zefox.net
Groupes : sci.electronics.repairDate : 19. May 2025, 16:05:13
Autres entêtes
Organisation : A noiseless patient Spider
Message-ID : <100fhb9$1m3rv$2@dont-email.me>
References : 1
User-Agent : tin/2.6.4-20241224 ("Helmsdale") (FreeBSD/14.2-STABLE (arm64))
Ed Vance <
Ed.Vance@f10.n1.z11969.fidonet.org> wrote:
The UPS has always been plugged in a A.C. outlet but one day I presses the
Power On button and it didn't come on.
Would replacing the Battery correct this problem?
It might, but I'd start by simply measuring the battery voltage.
If it's ok, a new battery seems unlikely to help by itself.
The inverter/charger units I have won't do anything at all
without a live battery and they're configured as UPS units.
The battery needn't be good, but can't be stone-dead.
HTH,
bob prohaska